What is the process for reverse osmosis maintenance systems?

In the field of water treatment, reverse osmosis systems, with their efficient desalination and purification capabilities, have become core equipment for pure water production in industries such as electronics, chemicals, and power generation. However, the stable operation of the system directly impacts production continuity and water quality compliance.
Scientific maintenance and management are crucial for extending equipment lifespan and reducing operating costs. Conversely, improper reverse osmosis maintenance can easily lead to problems such as membrane fouling and decreased water production efficiency. This article will summarize the key maintenance points of ro systems, providing a reference for practical work.

1. Pretreatment is the first line of defense in reverse osmosis maintenance

Pretreatment is the foundation for the stable operation of reverse osmosis systems. Its core function is to remove suspended solids, colloids, organic matter, residual chlorine, and other impurities from the raw water. Thus, prevent these substances from causing irreversible damage to the RO membrane. Given the complex nature of raw water quality, it is necessary to optimize the pretreatment process and strengthen maintenance accordingly.

pretreatment reverse osmosis maintenance

Quartz sand filters require regular backwashing and forward flushing, typically every 24-48 hours. Backwashing time should be controlled at 10-15 minutes. The filter media should be replaced promptly when the pressure difference between the inlet and outlet exceeds 0.1 MPa.
Activated carbon filters require close monitoring of residual chlorine removal effectiveness to ensure the residual chlorine content in the effluent is below 0.1 mg/L. After 6-12 months of use, the adsorption capacity of the filter media should be checked, and regeneration or replacement should be performed if necessary.
The security filter is the last barrier in the pretreatment process, and the filter element needs to be replaced regularly. Replacement is usually required immediately when the pressure difference reaches 0.2 MPa. Strict aseptic procedures must be followed during the replacement process to prevent secondary contamination.

security filter reverse osmosis maintenance

2. Precise maintenance of ro membrane elements extends their service life

As a core consumable in water treatment systems, the performance degradation of RO membranes directly affects water quality and operational efficiency. Therefore, standardized maintenance work is necessary, focusing on operational control, shutdown protection, and contamination cleaning.

Umkehrosmosemembran

1. Process control during operation

① The inlet water temperature needs to be strictly controlled and maintained within the range of 15-35℃. For every 1℃ increase in temperature, the membrane flux increases by approximately 2.5%-3%. Therefore, overheating should be avoided to prevent accelerated aging of the membrane elements.
② The inlet water pH should be controlled between 2 and 11 (during operation) to avoid corrosion of the membrane elements by extreme acidic or alkaline environments and ensure stable membrane separation performance.

2. Protection during shutdown

Based on the duration of downtime, differentiated protective measures are implemented to prevent drying and oxidative damage to the membrane elements.
① Short-term shutdown (≤72 hours): After shutdown, rinse the membrane elements with clean water to ensure they remain fully submerged. Regular circulation should be initiated during this period to prevent microbial growth in stagnant water.
② Long-term shutdown (>72 hours): Immerse the membrane elements in a 0.5%-1.0% sodium bisulfite solution to isolate them from air and prevent oxidation. The protective solution needs to be replaced monthly to maintain its effectiveness.
Regularly inspect the membrane element seals. If any leaks or signs of aging are found, replace them promptly to prevent mixing of concentrated water and permeate, which would affect the water quality.

3. Contamination assessment and cleaning procedures

During RO membrane operation, scale, microorganisms and organics tend to deposit on the membrane surface. Clean immediately if any of these occur: ≥10% drop in permeate flow rate, ≥5% reduction in salt rejection rate, or ≥15% rise in inlet-outlet pressure difference.

①Pre-cleaning prep: Identify contamination type via water quality testing and select matching cleaning agent. Blind cleaning (damaging to membrane elements) is strictly forbidden.

②Targeted cleaners:

  • Inorganic scale (e.g., calcium carbonate/sulfate): Acidic cleaners (citric acid, dilute hydrochloric acid)
  • Organic/microbial contamination: Alkaline cleaners (sodium hydroxide + surfactant)

③Cleaning parameters: Maintain temperature at 30–35℃, set flow rate to 1.5× normal operating level; duration: 30–90 minutes (adjust by contamination severity).

④Post-cleaning recovery: Rinse membrane elements thoroughly with clean water until permeate quality meets standards, then resume normal operation.

⑤Cleaning frequency: Clean every 3–6 months. Over-frequent cleaning damages the membrane’s dense layer and shortens its service life.

3. Establish a standardized reverse osmosis maintenance system

In addition to the above inspections, we also need to establish a comprehensive maintenance and management system and stock sufficient qualified spare parts (such as filter elements, seals, cleaning agents, and membrane elements) to avoid maintenance delays due to a shortage of spare parts.
Furthermore, maintain a clean and dry operating environment for the equipment, regularly check pipelines and valves for leaks and corrosion, and address potential problems promptly. Conduct regular comprehensive inspections of the system, including the pump operating status, electrical control system, and dosing equipment, and maintain a maintenance log to achieve full lifecycle management.

UNSERE FABRIK
WORKSHOPS

Die 2018 gegründete Guangdong XinJieYuan Environmental Protection Technology Co. Ltd. ist ein integriertes Umweltunternehmen, das sich auf wissenschaftliche Forschung, Produktion und Vertrieb spezialisiert hat und über ein professionelles Team von 20 bis 99 Mitarbeitern und eine gut ausgestattete Anlage mit einer Fläche von etwa 1.800 Quadratmetern im Panyu District in Guangzhou, China, verfügt. Das Unternehmen liegt strategisch günstig im Herzen des Perlflussdeltas und nutzt seine erstklassige Lage, um effiziente Abläufe zu unterstützen, das Geschäft in den Bereichen Landwirtschaft, Chemietechnik, medizinische Versorgung und Lebensmittelverarbeitung auszuweiten (in den Bereichen Forschung und Entwicklung von Umweltausrüstungen, Wasser- und Schlammbehandlung und ökologische Wiederherstellung) und nahtlose Import- und Exportvorgänge für globale Kunden zu erleichtern.

Werkstatt für Wasseraufbereitungsanlagen
Werkstatt für Wasseraufbereitungsanlagen
Werkstatt für Wasseraufbereitungsanlagen
Werkstatt für Wasseraufbereitungsanlagen
Werkstatt für Wasseraufbereitungsanlagen
Werkstatt für Wasseraufbereitungsanlagen

FAQ

Wir passen die Geräteparameter und Aufbereitungslösungen an Ihren Wasserbedarf an (z. B. Wasserqualität, Spannung, Verfahren usw.), und alle Produkte entsprechen den internationalen universellen Standards (einschließlich ISO, CE usw.) mit vollständigen Zertifizierungsunterlagen. Von der Auswahl der Geräte über die Installation bis hin zur Wartung nach dem Verkauf bietet unser professionelles technisches Team Unterstützung über den gesamten Lebenszyklus. Durch die Nutzung unseres globalen kooperativen Logistiknetzes gewährleisten wir eine schnelle Lieferung mit einer Reaktionszeit von höchstens 24 Stunden nach dem Verkauf und lösen alle Probleme, die Sie bei der Beschaffung und Nutzung im Ausland haben könnten.

-Wir erstellen in der Regel innerhalb von 24 Stunden nach Eingang Ihrer Anfrage ein Angebot.
(Außer an Wochenenden und Feiertagen).
-Wenn Sie den Preis sehr dringend benötigen, rufen Sie uns bitte an.
oder kontaktieren Sie uns auf andere Weise, damit wir Ihnen ein Angebot machen können.
-Es hängt von der Bestellmenge und der Spannung der Maschine ab, die Sie benötigen.
-Normalerweise können wir innerhalb von 7-15 Tagen für kleine Mengen versenden,
und etwa 30 Tage für große Mengen.
Bei Sonderspannungen benötigen wir etwa 40 Tage für die Produktion.
-Diese Maschine ist sehr einfach zu installieren. Die Maschine erhalten Sie 
montiert ist. Sie müssen nur die Schritte auf unserer englischen Seite befolgen 
Anleitung und Video. Wenn große Kapazität von Maschinen, können wir arrangieren 
Ingenieur, der bei der Installation hilft.
-T/T, Western Union, MoneyGram und L/C bei Sicht. Dies ist verhandelbar.
Nachdem wir die Bestellung bestätigt haben, sende ich Ihnen den Kaufvertrag mit unserem 
Bankverbindung des Unternehmens. Sie können Geld an unser Unternehmen überweisen 
Bankkonto per T/T. Oder Sie können wählen, um online zu bestellen.
Die Maschine wird in einer Standard-Exportkiste aus Sperrholz verpackt.
Es eignet sich für den Langzeitversand per Schiff/Luft/Zug.
Es könnte auf dem See-, Luft- oder Bahnweg verschickt werden.
Bitte setzen Sie sich vor der Bestellung mit uns in Verbindung.
-Wir bieten 1 Jahr Garantie. Es bedeutet, wenn es irgendwelche Teile ist 
innerhalb eines Jahres kaputt geht, senden wir Ihnen kostenlos Ersatzteile zu.
-1. Wir halten gute Qualität und wettbewerbsfähigen Preis zu gewährleisten, unsere Kunden profitieren
-2. Wir respektieren jeden Kunden als unseren Freund und wir aufrichtig tun Geschäft 
und sich mit ihnen anfreunden, ganz gleich, woher sie kommen.

Preis anfragen

Dieses Feld ist erforderlich.
Dieses Feld ist erforderlich.

Ausgewählte Artikel


Nach oben blättern

Bitte füllen Sie die Informationen aus, und wir werden Ihnen innerhalb von 24 Stunden antworten.

Plaudern wir ein wenig