What is the process for reverse osmosis maintenance systems?

In the field of water treatment, sistem osmosis terbalik, with their efficient desalination and purification capabilities, have become core equipment for pure water production in industries such as electronics, chemicals, and power generation. However, the stable operation of the system directly impacts production continuity and water quality compliance.
Scientific maintenance and management are crucial for extending equipment lifespan and reducing operating costs. Conversely, improper reverse osmosis maintenance can easily lead to problems such as membrane fouling and decreased water production efficiency. This article will summarize the key maintenance points of ro systems, providing a reference for practical work.

1. Pretreatment is the first line of defense in reverse osmosis maintenance

Pretreatment is the foundation for the stable operation of reverse osmosis systems. Its core function is to remove suspended solids, colloids, organic matter, residual chlorine, and other impurities from the raw water. Thus, prevent these substances from causing irreversible damage to the RO membrane. Given the complex nature of raw water quality, it is necessary to optimize the pretreatment process and strengthen maintenance accordingly.

pretreatment reverse osmosis maintenance

Quartz sand filters require regular backwashing and forward flushing, typically every 24-48 hours. Backwashing time should be controlled at 10-15 minutes. The filter media should be replaced promptly when the pressure difference between the inlet and outlet exceeds 0.1 MPa.
Activated carbon filters require close monitoring of residual chlorine removal effectiveness to ensure the residual chlorine content in the effluent is below 0.1 mg/L. After 6-12 months of use, the adsorption capacity of the filter media should be checked, and regeneration or replacement should be performed if necessary.
The security filter is the last barrier in the pretreatment process, and the filter element needs to be replaced regularly. Replacement is usually required immediately when the pressure difference reaches 0.2 MPa. Strict aseptic procedures must be followed during the replacement process to prevent secondary contamination.

security filter reverse osmosis maintenance

2. Precise maintenance of ro membrane elements extends their service life

As a core consumable in water treatment systems, the performance degradation of RO membranes directly affects water quality and operational efficiency. Therefore, standardized maintenance work is necessary, focusing on operational control, shutdown protection, and contamination cleaning.

reverse osmosis membrane

1. Process control during operation

① The inlet water temperature needs to be strictly controlled and maintained within the range of 15-35℃. For every 1℃ increase in temperature, the membrane flux increases by approximately 2.5%-3%. Therefore, overheating should be avoided to prevent accelerated aging of the membrane elements.
② The inlet water pH should be controlled between 2 and 11 (during operation) to avoid corrosion of the membrane elements by extreme acidic or alkaline environments and ensure stable membrane separation performance.

2. Protection during shutdown

Based on the duration of downtime, differentiated protective measures are implemented to prevent drying and oxidative damage to the membrane elements.
① Short-term shutdown (≤72 hours): After shutdown, rinse the membrane elements with clean water to ensure they remain fully submerged. Regular circulation should be initiated during this period to prevent microbial growth in stagnant water.
② Long-term shutdown (>72 hours): Immerse the membrane elements in a 0.5%-1.0% sodium bisulfite solution to isolate them from air and prevent oxidation. The protective solution needs to be replaced monthly to maintain its effectiveness.
Regularly inspect the membrane element seals. If any leaks or signs of aging are found, replace them promptly to prevent mixing of concentrated water and permeate, which would affect the water quality.

3. Contamination assessment and cleaning procedures

During RO membrane operation, scale, microorganisms and organics tend to deposit on the membrane surface. Clean immediately if any of these occur: ≥10% drop in permeate flow rate, ≥5% reduction in salt rejection rate, or ≥15% rise in inlet-outlet pressure difference.

①Pre-cleaning prep: Identify contamination type via water quality testing and select matching cleaning agent. Blind cleaning (damaging to membrane elements) is strictly forbidden.

②Targeted cleaners:

  • Inorganic scale (e.g., calcium carbonate/sulfate): Acidic cleaners (citric acid, dilute hydrochloric acid)
  • Organic/microbial contamination: Alkaline cleaners (sodium hydroxide + surfactant)

③Cleaning parameters: Maintain temperature at 30–35℃, set flow rate to 1.5× normal operating level; duration: 30–90 minutes (adjust by contamination severity).

④Post-cleaning recovery: Rinse membrane elements thoroughly with clean water until permeate quality meets standards, then resume normal operation.

⑤Cleaning frequency: Clean every 3–6 months. Over-frequent cleaning damages the membrane’s dense layer and shortens its service life.

3. Establish a standardized reverse osmosis maintenance system

In addition to the above inspections, we also need to establish a comprehensive maintenance and management system and stock sufficient qualified spare parts (such as filter elements, seals, cleaning agents, and membrane elements) to avoid maintenance delays due to a shortage of spare parts.
Furthermore, maintain a clean and dry operating environment for the equipment, regularly check pipelines and valves for leaks and corrosion, and address potential problems promptly. Conduct regular comprehensive inspections of the system, including the pump operating status, electrical control system, and dosing equipment, and maintain a maintenance log to achieve full lifecycle management.

PABRIK KAMI
LOKAKARYA

Guangdong XinJieYuan Environmental Protection Technology Co, Ltd, didirikan pada tahun 2018, adalah perusahaan lingkungan terintegrasi yang mengkhususkan diri dalam penelitian ilmiah, produksi dan penjualan, dengan tim profesional yang terdiri dari 20 hingga 99 anggota dan fasilitas lengkap seluas 1.800 meter persegi di Distrik Panyu, Guangzhou, Cina. Berlokasi strategis di inti Pearl River Delta, perusahaan ini memanfaatkan lokasi utamanya untuk mendukung operasi yang efisien, memperluas bisnis di bidang pertanian, teknik kimia, perawatan medis, dan industri pengolahan makanan (meliputi R&D peralatan lingkungan, pengolahan air/lumpur, dan restorasi ekologi), dan memfasilitasi operasi ekspor-impor yang lancar untuk klien global.

bengkel peralatan pengolahan air
bengkel peralatan pengolahan air
bengkel peralatan pengolahan air
bengkel peralatan pengolahan air
bengkel peralatan pengolahan air
bengkel peralatan pengolahan air

PERTANYAAN YANG SERING DIAJUKAN

Kami menyesuaikan parameter peralatan dan solusi pengolahan berdasarkan kebutuhan air Anda (seperti kualitas air, voltase, proses, dll.), dan semua produk mematuhi standar universal internasional (termasuk ISO, CE, dll.) dengan dokumen sertifikasi yang lengkap. Dari pemilihan peralatan dan panduan pemasangan hingga pemeliharaan purnajual, tim teknis profesional kami menawarkan dukungan siklus penuh. Memanfaatkan jaringan logistik koperasi global kami, kami memastikan pengiriman cepat dengan waktu respons purna jual tidak lebih dari 24 jam, sepenuhnya menyelesaikan masalah apa pun yang mungkin Anda miliki selama pengadaan dan penggunaan di luar negeri.

-Kami biasanya mengutip dalam waktu 24 jam setelah kami mendapatkan pertanyaan Anda
(Kecuali akhir pekan dan hari libur).
-Jika Anda sangat mendesak untuk mendapatkan harga, silakan hubungi kami
atau hubungi kami dengan cara lain agar kami dapat memberikan penawaran harga.
-Tergantung pada jumlah pesanan dan voltase mesin yang Anda butuhkan.
-Biasanya kami dapat mengirimkan dalam waktu 7-15 hari untuk jumlah kecil,
dan sekitar 30 hari untuk jumlah besar.
Tegangan khusus yang kami perlukan sekitar 40 hari untuk produksi.
-Mesin ini sangat mudah dipasang. Mesin yang Anda terima 
sudah terpasang. Anda hanya perlu mengikuti langkah-langkah di halaman bahasa Inggris kami 
instruksi dan video. Jika kapasitas mesin besar, kami dapat mengatur 
insinyur untuk membantu pemasangan.
-T / T, Western Union, MoneyGram dan L / C pada pandangan. Ini bisa dinegosiasikan.
Setelah kami mengkonfirmasi pesanan, saya akan mengirimkan kontrak penjualan dengan 
informasi bank perusahaan. Anda dapat mentransfer uang ke perusahaan kami 
rekening bank melalui T / T. Atau Anda dapat memilih untuk melakukan pemesanan secara online.
-Mesin akan dikemas dengan kotak kayu lapis standar ekspor.
Sangat cocok untuk pengiriman jangka panjang melalui laut/udara/kereta api.
-Bisa dikirim melalui laut, udara, kereta api.
Mohon konfirmasi dengan kami sebelum melakukan pemesanan.
-Kami memberikan garansi 1 tahun. Ini berarti ketika ada bagian mana pun 
rusak dalam satu tahun, kami akan mengirimkan suku cadang kepada Anda secara gratis.
-1. Kami menjaga kualitas yang baik dan harga yang kompetitif untuk memastikan pelanggan kami mendapatkan keuntungan
-2. Kami menghormati setiap pelanggan sebagai teman kami dan kami dengan tulus menjalankan bisnis 
dan berteman dengan mereka, dari mana pun mereka berasal.

Harga Permintaan

Bidang ini wajib diisi.
Bidang ini wajib diisi.

Artikel Pilihan


Gulir ke Atas

Silakan isi informasi, dan kami akan membalas Anda dalam waktu 24 jam.

Mari kita mengobrol