Does reverse osmosis remove fluoride?

Can reverse osmosis remove fluoride from water? To answer this question, we must first examine fluoride itself.

A common trace component in drinking water, high levels can potentially harm human health, such as damage to teeth and bones. For this reason, many families consider water purification to improve water quality. And reverse osmosis technology is a superior option. It not only effectively removes fluoride from water, but also does so at a high rate and with a reliable process. Make it an ideal solution for addressing excessive fluoride levels in drinking water.

反滲透系統

The core principle of reverse osmosis technology

To determine whether reverse osmosis can remove fluoride, we first need to understand its core logic for water purification. RO uses a high-pressure pump to apply external force, forcing water molecules in the raw water to reverse through a selectively permeable “reverse osmosis membrane,” while trapping impurities and ions in the water on the other side of the membrane, ultimately producing pure drinking water.

What is the function of reverse osmosis membrane?

The pore size of reverse osmosis membranes is extremely small, typically less than 0.0001 microns—much smaller than fluoride ions (approximately 0.133 nanometers in diameter) and other common ions in water, such as calcium and magnesium. Therefore, this “physical interception” mechanism effectively blocks the passage of fluoride ions, thereby achieving fluoride removal.

reverse osmosis membrane

How efficient is reverse osmosis at removing fluoride?

Reverse osmosis technology is highly effective in removing fluoride. Under normal operating conditions, a qualified reverse osmosis system typically achieves a fluoride removal rate exceeding 90%, with some high-quality systems even reaching 95%-99%.
For example, if the raw water has a fluoride content of 1.5 mg/L, reverse osmosis treatment can reduce the fluoride content in the effluent to below 0.15 mg/L, which is far below the national standard.

What situations will affect the fluoride removal effect?

  • Quality and condition of reverse osmosis membrane

If the RO membrane becomes damaged, aged, or clogged with contaminants (such as calcium scale or organic matter). It can cause “membrane penetration,” allowing impurities like fluoride ions to leak out, reducing the removal rate. Therefore, it’s important to regularly replace and maintain the reverse osmosis membrane (usually every 1-2 years is recommended).

  • Raw water quality conditions

The pH value of the raw water affects the membrane’s retention efficiency. When the pH value is too low, fluoride ions easily penetrate the reverse osmosis membrane. It will result in a decrease in fluoride removal efficiency. It is generally recommended to adjust the raw water pH value to between 6.5 and 8.5 to improve the retention efficiency.

  • System operating parameters​

The operating pressure, influent flow rate, and recovery rate of a reverse osmosis system also affect fluoride removal effectiveness. If the rated operating pressure is insufficient, impurity retention efficiency will decrease.
If the recovery rate is too high, the concentration of impurities (including fluoride ions) on the membrane surface will increase, reducing the fluoride removal efficiency. We generally recommend controlling the system recovery rate between 50% and 75% to balance water production and fluoride removal effectiveness.

What should I pay attention to ?

1. Equipped with pre-treatment device

If the raw water has a high hardness (high calcium and magnesium ion content) or contains a lot of organic matter and sediment, we need to install a pre-treatment device before the reverse osmosis system. Pre-treatment devices include pre-filters, activated carbon filters, and water softeners.

pretreatment system

2. Regularly test the water quality

Regularly (e.g., every 3-6 months) test the fluoride content in the effluent of the reverse osmosis system. In order to resolve any issues with decreased fluoride removal efficiency (e.g., replacing membranes, adjusting system parameters).

3. Pay attention to the “wastewater” problem

During operation, reverse osmosis systems generate a certain amount of “concentrated water.” This concentrated water should not be discharged directly into the soil or near drinking water sources to avoid local fluoride accumulation and contamination. Instead, it can be used for flushing toilets, mopping floors, and irrigation. But careful attention should be paid to the concentration to avoid harming plants.

Summarize

Families or businesses struggling with excessive fluoride in their drinking water should choose a standard reverse osmosis water purification system and perform routine maintenance to ensure safe, low-fluoride drinking water.

If you have further questions about this issue, please feel free to contact us for answers.

聯絡新傑源

我們的工廠
工作坊

廣東新潔源環保科技有限公司成立於2018年,是一家集科研、生產、銷售於一體的環保企業,在中國廣州番禺區擁有一支20至99人的專業團隊和一個佔地約1800平方米、設備完善的廠房。公司位於珠江三角洲的核心地帶,擁有得天獨厚的地理優勢,能有效地支援業務運作,拓展農業、化工、醫療和食品加工等行業的業務(涵蓋環保設備研發、水/污泥處理和生態修復等領域),並為全球客戶提供無縫的進出口業務。.

水處理設備車間
水處理設備車間
水處理設備車間
水處理設備車間
水處理設備車間
水處理設備車間

常見問題

我們根據您的用水需求(如水質、電壓、製程等)量身定制設備參數和處理方案,所有產品均符合國際通用標準(包括ISO、CE等),認證文件齊全。從設備選型、安裝指導到售後維護,我們的專業技術團隊提供全周期的支援。憑藉全球合作的物流網路,我們確保快速交貨,售後反應時間不超過 24 小時,充分解決您在海外採購和使用過程中的任何疑慮。.

-我們通常在收到您的詢價後 24 小時內報價。
(週末及假日除外)。.
-如果您急需得到價格,請來電我們。
或以其他方式聯絡我們,以便我們為您提供報價。.
-這取決於訂單數量和您需要的機器電壓。.
-小量貨品通常可於 7-15 天內出貨、,
大量採購約需 30 天。.
特殊電壓我們可能需要大約 40 天的生產時間。.
-本機器非常容易安裝。您收到的機器 
已組裝完成。您只需按照我們的英文網頁上的步驟操作即可。 
說明和視訊。如果機器容量大,我們可以安排 
工程師協助安裝。.
-T/T、西聯、速匯金和見證信用證。這是可以商量的。.
當我們確認訂單後,我會寄給您我們的銷售合約。 
公司銀行資訊。您可以向本公司匯款 
銀行帳戶以電匯付款。或者您也可以選擇線上下單。.
-機器將以標準出口夾板箱包裝。.
適合長時間海運/空運/火車運輸。.
-可透過海運、空運或火車運送。.
請在下單前與我們確認。.
-我們提供 1 年保固。這表示當有任何零件 
一年內損壞,我們將免費寄送備用零件給您。.
-1.我們保持良好的品質和有競爭力的價格,以確保我們的客戶受益。
-2.我們尊重每一位顧客,視他們為朋友,並誠心誠意地與他們做生意。 
並與他們交朋友,無論他們來自何方。.

詢價

此欄位必須填寫。.
此欄位必須填寫。.

精選文章


滾動到頂端

請填寫資料,我們會在 24 小時內回覆您。.

我們來聊聊