In the field of water treatment, reverse osmosis systems, with their efficient desalination and purification capabilities, have become core equipment for pure water production in industries such as electronics, chemicals, and power generation. However, the stable operation of the system directly impacts production continuity and water quality compliance.
科學的維護和管理對於延長設備壽命和降低運行成本至關重要。反之,不當的反滲透維護很容易導致膜結垢、產水效率降低等問題。本文將總結 ro 系統的維護重點,為實際工作提供參考。.

1. Pretreatment is the first line of defense in reverse osmosis maintenance

Pretreatment is the foundation for the stable operation of reverse osmosis systems. Its core function is to remove suspended solids, colloids, organic matter, residual chlorine, and other impurities from the raw water. Thus, prevent these substances from causing irreversible damage to the RO membrane. Given the complex nature of raw water quality, it is necessary to optimize the pretreatment process and strengthen maintenance accordingly.

預處理反滲透維護

Quartz sand filters require regular backwashing and forward flushing, typically every 24-48 hours. Backwashing time should be controlled at 10-15 minutes. The filter media should be replaced promptly when the pressure difference between the inlet and outlet exceeds 0.1 MPa.
Activated carbon filters require close monitoring of residual chlorine removal effectiveness to ensure the residual chlorine content in the effluent is below 0.1 mg/L. After 6-12 months of use, the adsorption capacity of the filter media should be checked, and regeneration or replacement should be performed if necessary.
The security filter is the last barrier in the pretreatment process, and the filter element needs to be replaced regularly. Replacement is usually required immediately when the pressure difference reaches 0.2 MPa. Strict aseptic procedures must be followed during the replacement process to prevent secondary contamination.

security filter reverse osmosis maintenance

2. Precise maintenance of ro membrane elements extends their service life

As a core consumable in water treatment systems, the performance degradation of RO membranes directly affects water quality and operational efficiency. Therefore, standardized maintenance work is necessary, focusing on operational control, shutdown protection, and contamination cleaning.

reverse osmosis membrane

1. Process control during operation

① The inlet water temperature needs to be strictly controlled and maintained within the range of 15-35℃. For every 1℃ increase in temperature, the membrane flux increases by approximately 2.5%-3%. Therefore, overheating should be avoided to prevent accelerated aging of the membrane elements.
② The inlet water pH should be controlled between 2 and 11 (during operation) to avoid corrosion of the membrane elements by extreme acidic or alkaline environments and ensure stable membrane separation performance.

2. Protection during shutdown

Based on the duration of downtime, differentiated protective measures are implemented to prevent drying and oxidative damage to the membrane elements.
① Short-term shutdown (≤72 hours): After shutdown, rinse the membrane elements with clean water to ensure they remain fully submerged. Regular circulation should be initiated during this period to prevent microbial growth in stagnant water.
② Long-term shutdown (>72 hours): Immerse the membrane elements in a 0.5%-1.0% sodium bisulfite solution to isolate them from air and prevent oxidation. The protective solution needs to be replaced monthly to maintain its effectiveness.
Regularly inspect the membrane element seals. If any leaks or signs of aging are found, replace them promptly to prevent mixing of concentrated water and permeate, which would affect the water quality.

3. Contamination assessment and cleaning procedures

During RO membrane operation, scale, microorganisms and organics tend to deposit on the membrane surface. Clean immediately if any of these occur: ≥10% drop in permeate flow rate, ≥5% reduction in salt rejection rate, or ≥15% rise in inlet-outlet pressure difference.

①Pre-cleaning prep: Identify contamination type via water quality testing and select matching cleaning agent. Blind cleaning (damaging to membrane elements) is strictly forbidden.

②Targeted cleaners:

  • Inorganic scale (e.g., calcium carbonate/sulfate): Acidic cleaners (citric acid, dilute hydrochloric acid)
  • Organic/microbial contamination: Alkaline cleaners (sodium hydroxide + surfactant)

③Cleaning parameters: Maintain temperature at 30–35℃, set flow rate to 1.5× normal operating level; duration: 30–90 minutes (adjust by contamination severity).

④Post-cleaning recovery: Rinse membrane elements thoroughly with clean water until permeate quality meets standards, then resume normal operation.

⑤Cleaning frequency: Clean every 3–6 months. Over-frequent cleaning damages the membrane’s dense layer and shortens its service life.

3. Establish a standardized reverse osmosis maintenance system

In addition to the above inspections, we also need to establish a comprehensive maintenance and management system and stock sufficient qualified spare parts (such as filter elements, seals, cleaning agents, and membrane elements) to avoid maintenance delays due to a shortage of spare parts.
Furthermore, maintain a clean and dry operating environment for the equipment, regularly check pipelines and valves for leaks and corrosion, and address potential problems promptly. Conduct regular comprehensive inspections of the system, including the pump operating status, electrical control system, and dosing equipment, and maintain a maintenance log to achieve full lifecycle management.

我們的工廠
工作坊

廣東新潔源環保科技有限公司成立於2018年,是一家集科研、生產、銷售於一體的環保企業,在中國廣州番禺區擁有一支20至99人的專業團隊和一個佔地約1800平方米、設備完善的廠房。公司位於珠江三角洲的核心地帶,擁有得天獨厚的地理優勢,能有效地支援業務運作,拓展農業、化工、醫療和食品加工等行業的業務(涵蓋環保設備研發、水/污泥處理和生態修復等領域),並為全球客戶提供無縫的進出口業務。.

水處理設備車間
水處理設備車間
水處理設備車間
水處理設備車間
水處理設備車間
水處理設備車間

常見問題

我們根據您的用水需求(如水質、電壓、製程等)量身定制設備參數和處理方案,所有產品均符合國際通用標準(包括ISO、CE等),認證文件齊全。從設備選型、安裝指導到售後維護,我們的專業技術團隊提供全周期的支援。憑藉全球合作的物流網路,我們確保快速交貨,售後反應時間不超過 24 小時,充分解決您在海外採購和使用過程中的任何疑慮。.

-我們通常在收到您的詢價後 24 小時內報價。
(週末及假日除外)。.
-如果您急需得到價格,請來電我們。
或以其他方式聯絡我們,以便我們為您提供報價。.
-這取決於訂單數量和您需要的機器電壓。.
-小量貨品通常可於 7-15 天內出貨、,
大量採購約需 30 天。.
特殊電壓我們可能需要大約 40 天的生產時間。.
-本機器非常容易安裝。您收到的機器 
已組裝完成。您只需按照我們的英文網頁上的步驟操作即可。 
說明和視訊。如果機器容量大,我們可以安排 
工程師協助安裝。.
-T/T、西聯、速匯金和見證信用證。這是可以商量的。.
當我們確認訂單後,我會寄給您我們的銷售合約。 
公司銀行資訊。您可以向本公司匯款 
銀行帳戶以電匯付款。或者您也可以選擇線上下單。.
-機器將以標準出口夾板箱包裝。.
適合長時間海運/空運/火車運輸。.
-可透過海運、空運或火車運送。.
請在下單前與我們確認。.
-我們提供 1 年保固。這表示當有任何零件 
一年內損壞,我們將免費寄送備用零件給您。.
-1.我們保持良好的品質和有競爭力的價格,以確保我們的客戶受益。
-2.我們尊重每一位顧客,視他們為朋友,並誠心誠意地與他們做生意。 
並與他們交朋友,無論他們來自何方。.

詢價

此欄位必須填寫。.
此欄位必須填寫。.

精選文章


滾動到頂端

請填寫資料,我們會在 24 小時內回覆您。.

我們來聊聊